- 15. Central air
   15.1. Specifications
   15.2. Instruction on coolant application
   15.3. Remarks at replacement of elements of central air of air
   15.4. Connection of elements of central air of air
   15.5. Check of elements of central air established on the car
   15.6. Installation of manometers for pressure measurement
   15.7. Pumping of atmospheric air from central air
   15.8. Charging of central air of air
   15.9. Check of level of a coolant
   15.10. Verification of operational characteristics
   15.11. Oil for greasing of the compressor of the conditioner
   15.12. Relay check
   15.13. Conditioner compressor
   15.14. Plug of coupling and pulley of the compressor of the conditioner
   15.15. Coil of initiation of coupling
   15.16. Compressor check on the car
   15.17. Sensor of threefold (double) pressure
   15.18. Fan and condenser
   15.19. Evaporator
   15.20. Check of the thermostatic sensor (termistor)
   15.21. Air filter of the evaporator
   15.22. Heating and ventilation block
   15.23. Heater block
   15.24. Fan
   15.25. Search and elimination of malfunctions
+ 16. Electric equipment
+ 17. Appendix
+ 18. Electroschemes






15.11. Oil for greasing of the compressor of the conditioner

Oil for greasing of the compressor of the conditioner circulates in system at operation of the compressor. At replacement of any element of central air of air at considerable leakage of a coolant add in system oil that its volume remained at initial level.

Oil volume: 140–160 cm3

Oil condition

PERFORMANCE ORDER
1. Oil should not contain moisture, a dust, metal particles etc.
2. Do not mix some oil of various types.
3. Moisture content in oil increases, if it remains open on air a long time. After oil use the capacity with oil is necessary for closing immediately tightly.

To check level of oil or to add oil it is necessary at operation of the engine on frequency of rotation of a cranked shaft of the engine idling and at high frequency of rotation of the fan.

At replacement of elements of system be convinced that added only a certain volume of oil.

Volume of the oil added at replacement:
Evaporator: 40 cm3
Condenser: 25 cm3
Dryer / receiver: 40 cm3
Compressor: 30 cm3
Tubes: 15 cm3