1. Connect station of service of central air of air, as is shown in drawing. |
2. Open the valve of low pressure and adjust it so that the manometer of low pressure showed pressure no more than 412 kPas. |
3. Place the container with a coolant in the water which has been heated up to temperature no more 40°C to support a vapor pressure in the container a little above, than a vapor pressure in system. |
4. Start the engine in a mode of the accelerated idling and turn on the conditioner. |
Prevention
Be convinced that support a container rack to interfere with hit of a liquid coolant through the party with low pressure as damage of the compressor of the conditioner is thus possible.
|
|
5. Charge system precisely established quantity of a coolant and close the delivery valve.
Quantity of a coolant: 575-625 g |