Hyundai Accent + 1. Maintenance instruction + 2. Engine + 3. Greasing system + 4. Cooling system + 5. Control, decrease in toxicity + 6. Fuel system + 7. Ignition system + 8. Coupling + 9. Transmission + 10. Axes and power shafts + 11. Suspension bracket + 12. Steering + 13. Brake system + 14. Body - 15. Central air 15.1. Specifications 15.2. Instruction on coolant application 15.3. Remarks at replacement of elements of central air of air 15.4. Connection of elements of central air of air 15.5. Check of elements of central air established on the car 15.6. Installation of manometers for pressure measurement 15.7. Pumping of atmospheric air from central air 15.8. Charging of central air of air 15.9. Check of level of a coolant 15.10. Verification of operational characteristics 15.11. Oil for greasing of the compressor of the conditioner 15.12. Relay check 15.13. Conditioner compressor 15.14. Plug of coupling and pulley of the compressor of the conditioner 15.15. Coil of initiation of coupling 15.16. Compressor check on the car 15.17. Sensor of threefold (double) pressure 15.18. Fan and condenser 15.19. Evaporator 15.20. Check of the thermostatic sensor (termistor) 15.21. Air filter of the evaporator 15.22. Heating and ventilation block 15.23. Heater block 15.24. Fan 15.25. Search and elimination of malfunctions + 16. Electric equipment + 17. Appendix + 18. Electroschemes
|
The sensor of threefold (double) pressure represents the combined switch of low pressure (to check quantity of a coolant), average pressure (for turning on of the fan of the condenser) and a high pressure (for overheat prevention).
The sensor is established in an exhaust pipe and when pressure becomes approximately equal 200 kPas or less, the condenser fan, thus excepting a compressor overheat is switched off. When pressure reaches 1400 kPas, the condenser fan is switched off, consumption of energy by it thus is prevented. When pressure reaches 3214 kPas, the compressor is switched off.
Removal
PERFORMANCE ORDER |
1. Discharge air central air. |
2. Disconnect the socket from the threefold (double) sensor of pressure. |
3. Turn out the threefold (double) sensor of pressure. |
|
Installation
PERFORMANCE ORDER |
1. Installation is carried out to sequences, return to removal. |
2. Pump out, charge and check air central air. |
|
|
|