Hyundai Accent

Repair and car operation



Hyundai Accent
+ 1. Maintenance instruction
+ 2. Engine
+ 3. Greasing system
+ 4. Cooling system
+ 5. Control, decrease in toxicity
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. Transmission
+ 10. Axes and power shafts
+ 11. Suspension bracket
+ 12. Steering
+ 13. Brake system
+ 14. Body
- 15. Central air
   15.1. Specifications
   15.2. Instruction on coolant application
   15.3. Remarks at replacement of elements of central air of air
   15.4. Connection of elements of central air of air
   15.5. Check of elements of central air established on the car
   15.6. Installation of manometers for pressure measurement
   15.7. Pumping of atmospheric air from central air
   15.8. Charging of central air of air
   15.9. Check of level of a coolant
   15.10. Verification of operational characteristics
   15.11. Oil for greasing of the compressor of the conditioner
   15.12. Relay check
   15.13. Conditioner compressor
   15.14. Plug of coupling and pulley of the compressor of the conditioner
   15.15. Coil of initiation of coupling
   15.16. Compressor check on the car
   15.17. Sensor of threefold (double) pressure
   15.18. Fan and condenser
   15.19. Evaporator
   15.20. Check of the thermostatic sensor (termistor)
   15.21. Air filter of the evaporator
   15.22. Heating and ventilation block
   15.23. Heater block
   15.24. Fan
   15.25. Search and elimination of malfunctions
+ 16. Electric equipment
+ 17. Appendix
+ 18. Electroschemes






15.4. Connection of elements of central air of air

Before installation check a new sealing ring on absence of damages and oil it for greasing of the compressor of the conditioner. Tighten bolts and nuts the demanded moment.


Internal elements of system of cooling are in a condition of chemical stability until reagent and oil for greasing are used pure, without moisture. The insignificant amount of dirt, moisture and damp oil can break chemical stability of system and working capacity or to put out of action air central air.

Precautionary measures

PERFORMANCE ORDER
1. Before separation of elements of central air of air it is necessary to prepare tools and adaptations for service of system so that to leave disconnected system elements on as smaller time is possible.
2. At separation of components of central air of air immediately close connections by the corresponding covers for an exception of hit of moisture in system.
3. All spare elements and tubes of central air of air should be stored in tight packing.
4. Repeatedly do not bend earlier formed tubes.
5. All tools, a coolant distributing a collector, measuring devices and tubes should be stored in a dry and pure place.